Equipment technical parameters
2.1 The range of product specifications that the equipment can produce (electrode size)
Dimension range of pole piece after punching
No. Name Dimensions (mm)
1 pole piece width W 50~280
2 pole piece height H 50~320
3 Tab height Ht 10~20
4 pole ear distance D 5~20
5 tab width Wt 30~60
The main technical parameters of the equipment
Item Equipment Parameter Index Parameter
1 Maximum feed width 350mm
2 Maximum processing area Automatic punching 340*280mm (manual punching 350*350mm)
3 Equipment running speed 1000-9000 times/h, efficiency (12PCS/min)
4 Die thickness requirements Thickness > 8mm
5 Feed control Feed speed and step distance can be adjusted
6 Feeding step accuracy ±0.1mm
7 Safety devices Infrared light barrier protection and safety shield
8 Feeding step accuracy <0.1mm
9 Operation interface Intelligent man-machine interface
10 Roll weight <50kg
11 Coil outer diameter <400mm
12 The service life of the punching knife is 10,000-50,000 times (depending on the quality of the knife mold and the precision of the machine adjustment)
13 Burr degree <0.02
14 material roll diameter 3 inches (inside diameter)
15 Waste recycling Automatic waste separation and recycling device
16 Operation Mode Auto/Manual Mode
17 Control system Intelligent microcomputer control
18 total power 3.6KW
19 Power supply voltage Single-phase AC220V
20 machine weight 1500kg
21 equipment size length 2.1 x width 0.98 x height 1.72 main components of the equipment
Serial number Part name Manufacturer
1 main motor Taiwan
2 Servo motor system Yaskawa, Japan
3 reducer Siemens
4 Touch screen Kunlun Tongtai
5 Time Relay, Solid State Omron
6 intermediate relay Siemens
7 Servo motor Yaskawa
8 speed control motor South Korea East Malaysia
9 safety light curtain
10 Clutch Taiwan Weizheng
11 cylinder AirTAC
12 Bearings IKO, NSK
13 Solenoid valve AirTAC
Site environment requirements
No. Parameter Index Parameter
1 Ambient temperature 0~40°C
2 relative humidity 20~90%RH
3 Power supply single-phase 220V, 50Hz
4 Voltage fluctuation range ±10%
5 Ground protection requirements <4Ω (multimeter measurement)
6 Compressed air 0.4~0.8Mpa(4-8kgf/cm2)
7 Pressure fluctuation range ±10%
8 The vacuum source is provided by Party A. The vacuum flow rate is 20L/MIN, and the vacuum degree is -40~-55KPa.
9 No corrosive gas, liquid, explosive gas on site