Ag-AgCl reference electrode

  • Brand: SOION TECH
  • Item No.: SOION-Ref-AgCl
  • Lead Time: 7 days

Product name: Detachable silver silver chloride electrode-3.8
English name:Ag/Agcl Electrode
Model specification: Ag/Agcl-3.8
Product Introduction:
The electrode glass tube has a length of 60mm and a diameter of 3.8mm. PTFE length 20mm, diameter 6mm.
The length of the electrode tail is 15mm. The porous ceramics at the front of the electrode are sealed by firing process.
The tail of the electrode adopts the plug-in process, which is convenient for adding the filling solution
After the long-term use of silver chloride coating falls off, it can be re-plated with silver chloride
Electrode jacket: glass tube with a diameter of 3.8mm

Product Name: Detachable Silver Silver Chloride Electrode-6.0
English name:Ag/Agcl Electrode
Model specification: Ag/Agcl-6.0
Product Introduction:
The electrode glass tube is 80mm in length and 6mm in diameter. PTFE length 20mm, diameter 10mm.
The length of the electrode tail is 15mm. The porous ceramics at the front of the electrode are sealed by firing process.
The tail of the electrode adopts the plug-in process, which is convenient for adding the filling solution
After the long-term use of silver chloride coating falls off, it can be re-plated with silver chloride
Electrode jacket: glass tube with a diameter of 6mm

The liquid-contacting part of the product is porous ceramics, and each electrode will leak when the protective cap is removed, which is a normal phenomenon, and you can add it yourself after the electrode liquid leaks. If you don’t understand the customer and think it’s a product quality problem, please don’t buy it. normal phenomenon.

If a calomel electrode or a silver chloride electrode is used to test alkaline or acidic liquids, the electrode will perform ion exchange with the acidic or alkaline electrolyte being tested.
That is, alkaline liquid or acidic reverse osmosis enters the electrode.
The inside of the electrode is saturated potassium chloride neutral liquid
Once a certain amount of alkaline liquid or acidic liquid is infiltrated, the electrode will deteriorate and be easily damaged.
In the literature, saturated calomel electrodes are used to measure alkaline or acidic liquids. This statement is correct, but the damage of the electrodes is not considered. As far as the electrodes themselves are concerned, it is recommended to select the corresponding electrodes to test the corresponding liquids.

Mercurous sulfate to test acidic liquid, saturated calomel electrode, silver chloride electrode, test neutral liquid, mercury oxide electrode to measure alkaline liquid, please choose the corresponding electrode correctly, so as not to damage the electrode and affect the test data.